Choosing a soundproof phone booth for your office looks straightforward on a brochure page. The isolation numbers, however, rarely compare directly across brands. This guide covers which numbers to request, which dimensions match which use case, and the logistics checklist to work through before you confirm an order.
What Does ‘Soundproof’ Actually Mean for an Office Phone Booth?
No booth is fully soundproof. The accurate claim is a measured reduction in decibels. Two different standards appear on spec sheets: Rw or STC measures how much a panel blocks sound in a lab, while DS,A per ISO 23351-1 measures the actual drop in speech level between inside and outside the booth as installed. A 30 dB DS,A result and a 45 dB Rw result can describe the same product. Always confirm which standard a number refers to before comparing booths from different manufacturers.
This is not a question of which brand is honest and which is not. It is a question of two measurement methods that produce different numbers for the same product. Rw and STC are measured in a laboratory on individual wall panels under tightly controlled conditions. The figures reflect how well the material blocks sound transmission, not how the finished booth performs as a whole.
DS,A per ISO 23351-1 measures the difference in speech level between inside and outside the booth after the unit is assembled and used as intended. This number is closer to what a user actually experiences, but it is typically lower than Rw because it accounts for leakage at door gaps, ventilation openings, and indirect sound paths (flanking paths).
The practical consequence: when you compare booths from two different manufacturers, make sure both are quoting the same standard. The numbers 45 and 30 can describe identical products if the first is the panel Rw and the second is the booth DS,A. Choosing on the larger number without checking the standard is the most common mistake at the evaluation stage.
How Much Isolation Is Enough for an Open-Plan Office?
The answer is not a fixed number. It is a function of your own office’s ambient noise level.
An active open-plan office typically runs at 50 to 65 dB(A). A confidential phone call requires the sound from inside the booth to drop below the ambient level outside. If your office ambient is 55 dB(A) and the booth delivers only 35 dB of reduction, sound from inside still registers at around 20 dB, which means speech fragments remain audible to nearby colleagues. A booth with 45 dB of reduction in the same environment pushes that down to 10 dB, which is effectively inaudible.
Buy to close the gap you actually have, not to match the largest number on a brochure. The recommended steps:
- Measure your office ambient with a sound level meter app during active working hours.
- Set your target: is “speech not clearly audible” sufficient, or do you need “completely undetectable”?
- Match that gap to the booth specification, and confirm the number uses the same standard throughout (DS,A or Rw).
Silent Box is designed with an isolation target of 35 to 50 dB depending on construction and materials used. The exact figure depends on how the booth is assembled and how the door seal seats in the field. For a more technical discussion of how isolation numbers translate to real office conditions, read how isolation numbers translate to real office conditions.
Dimensions: Which Size Covers Which Use Case?
Silent Box comes in three standard sizes. All prices exclude VAT.
| Variant | External Dimensions | Capacity | Price | Primary Use |
|---|---|---|---|---|
| Silent Box 1-Person | 100 x 100 x 220 cm | 1 person | Rp 35,000,000 | Phone calls, focused work |
| Silent Box 2-Person | 120 x 180 x 220 cm | 2 people | Rp 50,000,000 | 1-on-1 interviews, small briefings |
| Silent Box 4-Person | 180 x 200 x 220 cm | 4 people | Rp 65,000,000 | Small meetings, team discussions |
Custom sizes are available on request. The three figures above are starting points, not upper limits.
Comparison with the global market average: Single-person booths from world-class manufacturers (based on data read on 7 October 2026 from manufacturers’ official pages) average 108 x 97 x 224.5 cm. The Silent Box 1-person footprint of 100 x 100 cm is proportionally comparable to that average, not smaller.
For the 4-person variant, the Silent Box floor area is 3.60 m2 (180 x 200 cm), while the global market average for a four-person pod sits at 2.87 m2. That is roughly 25 percent more floor space, which means four people sit comfortably and there is room for laptops on the desk.
The 220 cm height advantage: Several global competitors sit in the 222 to 230 cm range and some require a minimum ceiling clearance of 240 cm at the installation point. At 220 cm, Silent Box fits more easily into offices with low ceilings or hanging ductwork. If your office has a dropped ceiling below 240 cm, verify the exact clearance at the intended placement point before ordering.
To work out how many units an open-plan office needs, see the guide on how to calculate how many units an open-plan office needs.
Ventilation: The Spec Most Buyers Forget Until After Delivery
Ventilation is not an optional feature. It is a prerequisite for a booth that gets used beyond the first few minutes.
A tightly sealed acoustic enclosure heats up within minutes of occupancy. CO2 builds, temperature rises, and the user opens the door to stay comfortable. The moment the door opens, every acoustic benefit disappears. Booths without properly designed air circulation are typically abandoned within the first few weeks of deployment.
Two ventilation approaches appear in the market:
- Active ventilation: A fan that pushes fresh air in and warm air out. It must run quietly enough not to degrade speech clarity inside the booth.
- Passive ventilation: Slots or gaps that allow natural air movement. The problem is that any slot large enough for effective air circulation is also a flanking path for sound, which measurably reduces isolation performance.
Silent Box uses a ceiling exhaust system designed to operate without interfering with speech clarity. For a technical explanation of how ventilation is designed inside a soundproof booth, there is a dedicated article covering air channel design, fan selection, and the effect on isolation numbers.
What’s Included vs. What You Still Need to Buy
Silent Box is not a shell that requires fit-out after delivery. Each unit ships with a complete interior, including:
- Three-layer fabric-wrapped acoustic panels on all interior walls
- LED lighting
- Power outlets and switches
- Timber flooring
- Wall-mounted desk
The prices in the table above cover all of these interior components. There are no additional fit-out costs for the standard specification. Two items sit outside the unit price:
- Installation: Available as an add-on service at Rp 2,000,000. This covers on-site assembly by the Kontraktor Studio team.
- VAT: Not included in the listed prices.
Production lead time is 14 to 30 days. That range depends on two main factors: whether a custom size requires special fabrication, and where your order falls in the production queue at that time. For a confirmed schedule, contact the team through the contact form. Do not use this general estimate as a project planning baseline without written confirmation.
Full specification details and variant options are available on the Silent Box product page.
Logistics Checklist Before You Confirm the Order
These are the questions a facilities manager typically needs answered before approving delivery. Work through each point before confirming the order.
- Freight elevator capacity: The Silent Box 1-person variant weighs approximately 160 to 200 kg. This is a logistics figure for delivery planning, not a construction quality claim. Confirm your building’s freight elevator can carry this weight together with the delivery crew and their equipment.
- Elevator interior dimensions and door widths: Booth panels need to travel disassembled. Measure the freight elevator interior and the width of every door along the delivery route from the loading dock to the placement point.
- Building management coordination: For upper floors, building management may require floor load documentation before approving placement. Coordinate this before the delivery date, not on the day.
- Corridor clearance: The booth is assembled on-site rather than brought in as a single piece, but the base panels still need maneuvering room. Verify that corridors are wide enough for panel movement.
For deliveries outside Jakarta, Silent Box ships across Indonesia because the modular construction is assembled on-site. Shipping costs and lead times are quoted per order based on the destination city and unit count. Full details are available on the delivery and installation outside Jakarta page.
When a Ready-Made Booth Is the Right Call vs. Building a Permanent Room
A ready-made booth makes sense when you need privacy within weeks, cannot undertake structural renovation, or need an asset that moves with the office. A permanent built room makes sense when usage is continuous across a full day, the acoustic target exceeds what a pod can deliver, or the layout is fixed for more than five years. Because Kontraktor Studio supplies both, the recommendation depends on your situation, not on a preferred product category.
A more detailed comparison to help the decision:
| Factor | Ready-Made Booth | Permanent Room |
|---|---|---|
| Renovation permit | Not required (treated as furniture) | Generally required |
| Time to usable | 14 to 30 days production | Weeks of construction |
| Cost certainty | Fixed price per unit | Variable, depends on site conditions |
| Relocatable | Yes, modular frame | No, sunk cost when lease ends |
| Very high STC target | Limited to booth construction capability | Can be engineered higher |
| Full-day continuous use | Less suited to continuous occupancy | Better suited |
If your office needs a radio broadcast room, recording studio, or a space with an STC target well above what a pod can deliver, a permanent room is the more appropriate solution. Kontraktor Studio handles both, including survey, measurement, design, and installation for permanent room projects.
FAQ
What dB reduction should a soundproof phone booth achieve in an open-plan office?
It depends on your ambient noise level. In a typical open-plan office running 55-65 dB(A), a booth with 35-40 dB reduction leaves speech fragments audible outside. A reduction of 45 dB or more in the same environment makes the caller effectively inaudible to colleagues nearby. Measure your office ambient level first, then match the booth spec to the gap you need to close.
What is the difference between STC, Rw, and DS,A for phone booth specs?
STC and Rw are laboratory panel transmission loss ratings. DS,A per ISO 23351-1 measures the actual drop in speech level between the inside and outside of an assembled booth. These are not equivalent numbers. A manufacturer can report 45 dB Rw for the wall panel and 30 dB DS,A for the finished booth. Always ask which standard applies to any isolation figure you are comparing.
Does a soundproof office phone booth need a building permit in Indonesia?
A freestanding modular booth is typically treated as furniture, not construction, and does not require a renovation or building permit under most commercial lease agreements in Indonesia. However, you should confirm with your building management before delivery, particularly regarding floor load documentation and any house rules about freestanding structures in the tenanted space.
How long does it take to receive and install an office phone booth?
Silent Box production takes 14 to 30 days after order confirmation. Delivery time depends on your location: within Jabodetabek it is typically a matter of days after production completes; to other islands it varies by freight mode and is quoted per order. Assembly on-site for one unit takes a half to one working day. Contact the team for a confirmed timeline based on your specific city and unit count.
Can a soundproof phone booth be moved when the office relocates?
Yes. The Silent Box frame is modular: it can be disassembled, transported, and reassembled at a new location. This is a material advantage over a built partition or dedicated acoustic room, which is a sunk cost the moment a lease ends. Plan for one to two working days for disassembly, crating, transport, and reassembly, plus coordination with the building management at both sites.
What ceiling height does an office need to fit a soundproof phone booth?
Silent Box stands 220 cm tall. For comfortable installation you need a finished ceiling height of at least 230 cm to allow for base levelling and minor clearance. Some global competitors require 240 cm minimum clearance. If your office has hanging ductwork or a dropped ceiling below 240 cm, verify the exact clearance at the intended placement point before ordering.
Summary
Isolation numbers on a booth spec sheet only mean something if you know the measurement standard behind them and your own office ambient level. The right dimensions depend on how many people will use the booth and how often. Ventilation determines whether the booth actually gets used or becomes expensive furniture that everyone avoids. And the decision between a ready-made booth and a permanent room comes down to usage intensity, acoustic target, and whether your office will relocate within the next five years.
If you already know the dimensions you need and want a confirmed technical spec and production schedule, the next step is the contact form. Get a confirmed spec sheet and lead time for your office.