Why Open-Plan Offices Need a Telephone Booth
Table of Contents
Open-plan offices encourage collaboration, but they create a problem that rarely gets addressed in the original design: there is nowhere to have a private conversation. Sensitive client calls, contract negotiations, HR consultations, and project updates that are not ready to be shared publicly all end up happening at desks, in corners, or in hallways, within earshot of people who should not be listening.
The problem runs in both directions. The person making the call speaks more quietly to avoid being overheard, which makes it harder for the person on the other end to hear clearly. At the same time, even at low volume, the conversation still reaches nearby colleagues. Those colleagues lose focus, and regaining that focus takes far longer than the interruption itself.
An office telephone booth works on a two-way acoustic separation principle. Sound generated inside the booth is attenuated before it reaches the open floor. Sound from the open floor is also attenuated before it enters the booth, so the person inside can speak clearly without background noise interfering. This is not purely a comfort issue. Conversations involving customer data, business strategy, or personnel matters carry real confidentiality implications, and an office without acoustic boundaries is an easy gap to overlook.
A well-designed booth is not just a box placed in a corner. A serious unit includes a ventilation system, interior acoustic lining, and built-in electrical fittings that make it comfortable to use for the full length of an actual call, not just for one minute before the occupant steps out because the air is stale.
How to Determine the Right Booth Size
The right size depends on how your team actually works. The single-person model (100 x 100 x 220 cm) suits individual calls and one-on-one video calls. The two-person variant (120 x 180 x 220 cm) works for one-on-one discussions, and the four-person unit (180 x 200 x 220 cm) functions as a small meeting room. The 220 cm height is a deliberate technical decision designed to fit offices with lower ceiling clearance.
Three standard Silent Box sizes are available on the Silent Box product page, each matched to a different use pattern:
| Variant | Dimensions (cm) | Primary Use | Price (excl. VAT) |
|---|---|---|---|
| 1 person | 100 x 100 x 220 | Private calls, individual video calls | Rp 35,000,000* |
| 2 persons | 120 x 180 x 220 | Two-party discussions, brief interviews | Rp 50,000,000* |
| 4 persons | 180 x 200 x 220 | Small meetings, team presentations | Rp 65,000,000* |
*Harga dapat berubah sewaktu-waktu.
*Harga yang tertulis adalah harga kisaran dan tidak mengikat.
When choosing between the single-person and two-person variant, the deciding factors are not only user count but also how frequently the booth will be used and how much floor space is available. The single-person vs. two-person booth comparison covers both options in detail and is worth reading before committing to either.
The 220 cm height is a practical technical decision with real consequences on site. Most office buildings in Indonesia, particularly those more than ten years old or with low-hanging AC duct runs, have an effective ceiling clearance in the 240 to 260 cm range. A booth taller than 225 cm can create problems getting through building entry doors or into freight elevators before it even reaches the destination floor. The 220 cm unit provides a safer margin for delivery and installation.
All dimensions above are starting points, not hard limits. If your floor plan requires something outside the standard sizes, custom dimensions are available on request.
Technical Specifications to Check Before Buying
The key items to verify are the ventilation system with a quiet exhaust fan, the sound isolation level measured in decibel reduction, and the interior fittings included with the unit. Confirm that the unit ships with power outlets, a data cable route, LED lighting, and interior acoustic panels already installed.
Here is a checklist of specifications to review before making a purchase decision:
- Ventilation system. A booth without a properly designed ventilation system becomes uncomfortable within minutes. The unit must have an exhaust fan that runs quietly, not a standard fan whose noise interferes with calls. The acoustic booth ventilation guide explains what to look for in more detail.
- Sound isolation level. A meaningful isolation figure is stated in decibel reduction of conversational sound, not in general terms like “soundproof.” Ask for the specific dB reduction the unit achieves and the measurement method used. Silent Box operates in the 35 to 50 dB range, depending on materials and construction.
- Interior acoustic panels. The inner walls of the booth are not decorative. Fabric-wrapped panels mounted inside absorb echo so that speech inside the booth sounds clear rather than reverberant.
- Electrical and data fittings. Power outlets, switches, LED lighting, and a data cable route should all be built in. Users should not need to run extension cables from outside the booth.
- Floor and desk. A timber floor finish and a small wall-mounted desk should be included in the unit, not sold as separate accessories. This is what separates a ready-to-use unit from an empty shell that still needs to be fitted out.
That last point is worth emphasising. A unit that includes a complete interior is fundamentally different in price from an empty shell. When comparing options, check that you are comparing equivalent specifications, not just the headline price.
Logistics Checklist Before Delivery
An acoustic booth is not standard furniture that can be carried up an escalator. Before confirming a delivery date, coordinate the following with your building management:
- Freight elevator capacity. The Silent Box single-person unit weighs approximately 160 to 200 kg. Many office building freight elevators have rated capacity limits that need to be verified before scheduling delivery. If the elevator capacity is insufficient, an alternative route must be agreed with building management from the outset.
- Corridor and door widths. Map the full route from the loading dock to the installation point and confirm that all corridors and doorways are wide enough for the unit’s external dimensions, including any turns along the way.
- Building management coordination. Some buildings require prior approval or restrict large deliveries to specific time windows outside standard business hours. Confirm the building’s requirements early.
- Floor load capacity. For upper-floor installations, confirm with building management whether a structural check is needed before delivery, not after the unit arrives.
- Final placement position. Decide exactly where the booth will stand before it arrives on site. The modular structure can be repositioned after assembly, but doing so is easier before electrical connections are made.
Thorough logistics planning prevents the scenario where a unit arrives at the building but cannot reach the destination floor because the freight elevator is too small or a corridor is too narrow. Two weeks of lead time for coordination before the scheduled delivery date is a reasonable standard.
Estimated Cost and Number of Units for Your Office
A commonly used guideline for open-plan offices is one phone booth unit per 8 to 12 employees. This is based on the assumption that at any given time, approximately 8 to 12 percent of total staff need a private space to speak simultaneously. If your team makes frequent client calls or external meetings, that ratio can be tightened to one unit per 6 to 8 people.
Standard Silent Box pricing is as follows, all excluding VAT:
- Silent Box 1 person (100 x 100 x 220 cm): Rp 35,000,000 per unit*
- Silent Box 2 persons (120 x 180 x 220 cm): Rp 50,000,000 per unit*
- Silent Box 4 persons (180 x 200 x 220 cm): Rp 65,000,000 per unit*
- Installation service: Rp 2,000,000* additional
These prices include a complete interior: fabric-wrapped acoustic panels, timber floor, wall-mounted desk, LED lighting, power outlets, switches, and exhaust fan. They are not bare-shell prices. Production lead time is 14 to 30 days from order confirmation.
For a calculation adjusted to your team size, available floor area, and budget, see the Silent Box cost and size breakdown or use the budget estimator on the site’s homepage. The output gives you a solid basis for internal discussion before a site survey takes place.
FAQ: Office Telephone Booth
- What are the standard dimensions of a single-person office telephone booth?
- The Silent Box single-person unit measures 100 x 100 x 220 cm. That footprint gives one user enough room to work at a wall-mounted desk with a task chair.
- Does installing an office telephone booth require a construction or renovation permit?
- No. An office telephone booth is a self-contained modular pod that stands on the floor without touching walls or ceilings, so no building renovation permit is required.
- How much does an office telephone booth weigh at delivery?
- The Silent Box single-person unit weighs approximately 160 to 200 kg. Confirm that figure with your building’s freight elevator capacity and delivery route before scheduling shipment.
- Will the air inside the booth get stuffy during a long call?
- Not if the booth includes a properly designed ventilation system with a quiet exhaust fan that continuously cycles air without letting noise escape.
- Can the booth be disassembled and moved if the office relocates?
- Yes. All Silent Box variants have a modular structure, so they can be disassembled, transported, and reassembled at a new location without damaging the main materials.
Conclusion
Choosing the right office telephone booth is not about picking the cheapest option or the largest one. It is about matching your team’s working patterns to a unit with specifications that genuinely support private, comfortable conversations every day.
Three things should be confirmed before purchase: the size that fits your user capacity and available floor space, the technical specifications covering ventilation and isolation in decibels, and your building’s logistical readiness to receive delivery. All three are easier to plan before order confirmation than to resolve when the unit is already at the building entrance.
View Full Specifications and Silent Box Size Options to review dimensions, interior fittings, and customisation options before making a decision.